4.3.6 Double O-ring Seal

Refer to Fig 32.


Fig 32

- During Pump assembly Install seal housings (156) to rotorcase securing

with screws (157).


- Install o-rings (159) into grooves within the inside bore of seal sleeve (158).

Note: Do not lubricate o-rings (159).

- Install o-rings (154) into grooves on the outside of seal sleeve (158).

- Install seal sleeve assemblies (158,159,154) into rotorcase (item 40 see fig

5.6 on page 60) ensure drive lugs locate with seal housings (156) correctly.


- Install o-rings (151) into the back of rotors (item 41 see fig 5.6 on page 60).

- Install seal sleeve (152) into rotors (item 41 see fig 5.6 on page 60)

ensuring drive lugs locate with rotor slots correctly.


- Install rotor assemblies to shafts (items 9 and 10 see fig 5.6 on page 60),

refer to section 4.2.3. Care must be taken when entering seal sleeve (152)
into o-rings (159).


- To disassemble reverse the above procedure.

- Before disassembling the seals, ensure pump is fully shutdown, refer to

section 3.5.