The Keypad Lock can support 100 (LK) / 2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA) users.
Each user is assigned a User Number in addition to the code used for entry.

Example
for v. G1:

USER TYPE

USER NUMBER

Master

01

Supervisor

02

Standard

04-97 (LK) 04-2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA)

1

For installation assistance, contact SARGENT at 800-810-WIRE (9473)

• SofLink™ Plus applications software must be used with (G1-PA & G1-TA) controller for programming

• The Master Code is always User “01”. The Master Code assigns the Emergency and Supervisory Codes.

It is also used for programming. Users are deleted through the Master Programming Code only

• Emergency code is a 10 second unlock time and will override a thrown deadbolt on a mortise lock

• The Supervisory Code is always User “02”. The Supervisory Code allows temporary lock out of selected users,

changes duration of unlock time, requests infrared interrogation output, and may add additional User Codes

Note: For LK

Emergency Code is at User location “02”
The Supervisory Code is at User location “03”

• The User Codes are entered at user location “04” or higher. User numbers do not have to be used or entered

sequentially

• The “Lock Out” user is location dependent. To ensure that all users are locked out of the keypad, program this

user at location "04"

• The “Passage” user has precedence over all users except the “Panic” user. The lock must be toggled back into

a locked state for other users to function

To Begin Programming:

The Lock Controller is preset at the factory with Master Code “1234”.
Entering 1234 * will unlock the lock allowing the lever handle to retract the latchbolt.

Initial Set-Up Procedures:

• The following are typical procedures to be used when setting up your Profile Series v. G1 lock

• If a mistake is made during any of the procedures, depress the “*” key several times until the yellow LED goes out

• If no keystroke is made in a 30 sec. timeframe, the programming up to that point will default and you will have

to start over

LK Programming (100 Users)

To determine programming steps for your lock:

If your label has an LK, use the programming below.
If your label has a G1-LU, G1-PK, G1-PA, G1-TU, G1-TP or G1-TA, turn to
programming in Section 3.

Change the Master Code

99# 1234*

Yellow LED blinks

50# 1#

Yellow LED blinks

New Master Code*

Yellow LED blinks quickly

New Master Code*

Yellow LED blinks slowly

*

Yellow LED goes out (If solid, see note)

This example uses the Factory Default 1234*
It is recommended not to use the factory default master code.

-

+

-

+

-

+

-

+

+

-

+

-

LK

Keypad Programming Instructions for the Profile Series LK and v. G1 Locks