3. WIRING
The 4341 can be used in many different applications but the drawings below show two
common ones: momentary release of a fail safe or fail secure electric lock and timed
release of a fail safe electric lock using the 4341 and the SARGENT TMR Time Delay.
Momentarily pressing the button will release the lock for the amount of time set on the
TMR. The wiring is also done in double break fashion so that even if the timer fails, the
button will be able to momentarily release the lock for added safety.
Wire Identification
Blue (NO 2)
NO 2
NO 1
Red (NC 1)
Red / White (COM 1)
Blue / White (COM 2)
Red
Blue
Blue/White
Power
Supply
+
-
Red/White
Timed double break release of fail safe lock
If fail safe
4341
4341
If fail secure
+
+
-
-
+
Blue
Yellow
Blue/White
Power
Supply
+
-
Red/White
Green
Red
Black
Red
White
TMR9
Electric
D.C Lock
Fail Safe
D.C Lock
Momentary release of fail safe or fail secure electric lock
Note: NO 1 and NC 2 are not
factory wired but may be wired
by the installer if desired
Rear of unit shown