SARGENT 2900 Fire Guard Electromechanical Closer-Holder User Manual

2900 fireguard, Position of arms and index settings

Advertising
background image

2900 FIREGUARD

®

Electromechanical Closer-Holder Device

Models 12-2960, 9-2960 and 2960 Multipoint Hold Open with
Rigid Arms Pull (Hinge) Side Installation Instructions

CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE
For assistance, contact SARGENT at 800-810-WIRE (9473) or www.sargentlock.com

A7395C

1

FOR MODELS 12-2960 / 9-2960 / 2960

1. Use dimensions shown on page 5 provided to locate

attaching screws on frame and door. Prepare holes

For concealed wire applications only

Locate and drill 1-1/8" diameter hole in the frame face for

3/4" conduit. (This is normally done at the time the frame

is being installed.) Connect conduit to backplate before

fastening backplate to frame

2. Attach backplate/closer assembly to frame. Position backplate

end with terminal strips away from hinge edge of frame

3. Make electrical connections:

A) 12-2960: Select and follow the wiring diagram from wiring

instructions sheet A7408 and 'Checkout Procedure' from Page 3.

B) 9-2960: Make solenoid wire connections with power input wires

from 12-2960 using two wire nuts provided in screw pack. Select

proper wiring diagram and 'Checkout Procedure' from Page 3.

4.

Make input power connections to the power supply board as directed.

NOTE: If electrical connections are to be made at a later date,

place cover on chassis now to prevent its loss, see Step F.

5. Installation of arm on closer: With appropriate size wrench, rotate

closer top spindle approximately 45ϒ (see step C below) (NOTE:

Closing both valves for door speed and latching speed makes this

procedure much easier). Position closer arm on bottom spindle

approximately parallel to the door and arm length away from hinge.

Secure arm with screw and washer

6. Installation of track on door: Remove end cap from track. Position

track with open side up. Insert roller end of closer arm in sliding

groove of track. With arm engaged in slide groove, slide track, into

position so that prepared holes on door align with track holes

Replace end cap and secure track to door

B

12-2960

2960

Backplate

Screw (6)

Backplate

Closer/Holder

Closer

Screw (4)

Smoke

Detector

Conduit Nut

(By others)

On/Off

Switch

Terminal

Strips

Terminal

Strips

3/4" Conduit

(By others)

Track Screw

(2 Reqd)

Track

Rigid Arm

9-2960

Companion unit (without electronics) not shown

Position of Arms and Index Settings

C

Right Hand Door

Index

Mark on

Spindle

View Looking Up When

Assembling Arm to Spindle

View Looking Up When

Assembling Arm to Spindle

Left Hand Door

Index

Mark on

Spindle

Approximate

Preload

Position of Main Arm

When Assembled to Spindle

MODEL

12-2960

NOTE:

Devices are handed

and must be the same

hand as door.

RH - Right Hand Door

LHR - Left hand Reverse

LH - Left Hand Door

RHR - Right Hand Reverse

MODELS

2960/9-2960

Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

Advertising