7
1331 STANDARD APPLICATION JH
HOLD OPEN ARM INSTRUCTIONS
Determine maximum degree of door opening required. Use a #16 drill. Drill and tap door and frame for 12-24 machine screws.
When using the included self tapping screw, predrill with a 3/32" drill.
*Provides maximum power for heavy or drafty doors
2
5
*
(120° - 12”)
180° - 10-1/8"
*
(120° - 6-12")
180° - 4-5/8"
2-
1/2"
1"
1-3/8"
12"
3/4"
With provided fasteners, install foot to frame and secure closer body to door with
power adjustment away from hinge
Power adjustment
Open door and insert foot into main arm. Close door fully, and while pushing arm as shown in picture,
tighten arm bolt
See page 5
for closer
adjustment
and cover
installation.
-
-
-
-
-
-
-
-
-
-
Flat mark
Frame
Frame
Nut faces down
Nut faces up
Left hand
door shown
Right hand
door shown
3
On both right and left hand doors, secure main arm to top spindle with screw and washer provided. Align flat mark as shown
4
Right hand shown, left hand similar.
Arm
Bolt
90°