Connecting pto kit hydraulic hoses, Pto k – Wheatheart S2000 Post Pounder User Manual

Page 33

Advertising
background image

W

HEATHEART

- P

OST

P

OUNDER

3. A

SSEMBLY

S2000 M

ODEL

3.3. I

NSTALLING

THE

PTO K

IT

IM15 R1

33

3.3.4. C

ONNECTING

PTO K

IT

H

YDRAULIC

H

OSES

Use the following procedure to connect the hydraulic hoses to the new compo-
nents included in the PTO Kit. Refer to Figure 10.2 in the Appendix for a detailed
hydraulic diagram.

1. Connect

the

hydraulic

pressure hose from the control valve to the PTO-

driven hydraulic pump’s pressure port.

2. Disconnect the fluid return hose (Part Number H34X84) from the fluid return

connector on the control valve (see Figure 3.14 below).

Figure 3.14 Hose Connections on the Control Valve

3. Divide the return hose into two lengths by measuring, marking, and cutting

the hose 37” from the 1/2” NPT connector.

4. Clean any debris left over from the end and interior of the two hoses, and

connect the two lengths as follows:

a. Connect the 1/2” NPT connector on the 37” length of hose to the oil filter

connector closest to the hydraulic tank. Connect the other end of the hose
to the hydraulic tank’s fluid return connector (the highest of the two
connectors), and secure it with the supplied hose clamp.

b. Connect the 3/4” NPT connector on the remaining length of hose to the

fluid intake connector on the hydraulic pump. Connect the other end of the
hose to the hydraulic tank’s supply connector (the lowest of the two
connectors), and secure it with the supplied hose clamp.

5. Connect the 3/4” NPT connector of the new hydraulic hose supplied with the

kit (H34X25) to the control valve return connector. Connect the remaining
1/2” connector to the other oil filter connector.

HYDRAULIC PRESSURE

FLUID RETURN

(H12X72P TO PTO PUMP)

H34X25 TO OIL FILTER

(H34X84 REMOVED)

Advertising