Appendix c - setup, Seed monitor console installation, Seed monitor console quick-start – Great Plains 3P4025AH Operator Manual User Manual

Page 121

Advertising
background image

2014-07-29

Table of Contents

Index

411-099M

Great Plains Manufacturing, Inc.

Table of Contents

Index

Appendix C - Setup

117

Appendix C - Setup

Seed Monitor Console Installation

Refer to Figure 99
The planter’s standard PM400 seed monitor system
includes a console

that needs to be mounted in the

cab of the tractor to be used with the planter.

The monitor includes cables for power

, speed

sensor

and sensor harnesses

. Installation

instructions are found in the included DICKEY-john

®

manual.

Power required is 12Vdc. Power color code is:
+ positive: red
- negative: black

The included bracket

requires customer-supplied

fasteners.

Transport and Field Safety Risk:
Mount the module so it is easy to monitor during planting, but
does not interfere with safe operation of the tractor in the field
or on public roads.

Seed Monitor Console Quick-Start

The PM400 factory defaults need to be changed to the
row configuration of a 3P4025AH planter, the speed
sensing used on all models, and may need to be
changed to metric mode. Pages 117 through 119
describe setting:

• metric data mode,

• planter row count,

• planter (swath-averaged) row spacing, and;

• initial speed calibration.

The monitor must be connected to +12 Vdc power to
enter these settings (the monitor does not need to be
connected to the implement harness).

See the DICKEY-john

®

11001-1372 manual for setting

limits and alarms.

Figure 99

PM400 Tractor Components

32005

1

3

4

2

5

1

2

3

4

5

Figure 100

Power-Up, Operate Screens

31928
31930

Advertising