Air and seeding system overview – Great Plains 3P4025AH Operator Manual User Manual

Page 37

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Operating Instructions

33

2014-07-29

Table of Contents

Index

411-099M

Air and Seeding System Overview

Refer to Figure 24, on page 32, and Figure 25.
The hydraulic fan

supplies air exclusively for meter

operation. Fan rpm is operator-adjusted via the tractor
circuit’s hydraulic flow control.

The manifold system

delivers fan air across the

planter. It includes passive internal design features to
balance pressure across the planter.

Separate pressurization tubes

route manifold air to

each row unit.

Seed is delivered from the seed box

by gravity

through the seed tubes

, to the inlet of the Air-Pro

®

seed meter.

A manually adjusted inlet shutter

controls the size of

the seed pool

at the base of the meter. The shutter

also minimizes air loss back up the seed inlet tube, and
is also used during row shut off. See page 60 for shutter
adjustments.

At the meter, pressurization air exits the meter through
the seed pockets

of the disk, and holds seed in the

pockets until released above the seed tube

.

In the seed tube, the seed sensor

detects passage of

seeds. Medium size and large seeds are counted
individually. With smaller seeds, most are detected,
allowing the monitor to detect stoppages.

Several rows have a pressure sensor port

for the

meter pressurization system. A line

from each of

these rows is connected to a chamber

to average the

pressures.

The averaged pressure is reported by a Magnehelic

®

gauge

visible to the tractor operator. See page 42 for

use of the gauge in making fan adjustments.

A sensor

in each seed tube reports seed passage to

the seed monitor. Larger seeds are counted individually.
For smaller seeds, the system acts as a blockage
monitor.

Note: Use of the special blank disk (page 64), and closing

the seed inlet shutter (page 60), are particularly
important when a sensor row is shut off.

Note: On any row, running a normal disk with no seed, or

with an open empty inlet, unbalances the air
system. Doing either at a sensor row causes the
gauge to mis-report as well.

Note: Do not operate in the ground with the fan shut off, or

with insufficient manifold pressure. The meters will
completely fill with seed. Meter clean-out may be
required to resume normal operation.

Figure 25

Air-Pro

®

Meter, Disk Side

31040

12

10

9

4

8

6

10

11

1

3

4

5

6

8

9

10

10

11

12

13

14

15

11

Advertising