General Application Troubleshooting

Problem

Cause

Solution

Excess
Material
Remaining

Field size different.

After ruling out metering problems, re-check geography.

Excessive gaps between applicator
passes.

Gap between opposing pass end trenches should be one
row space (e.g. 30in)

Material
Consumption
Too High

Field size different.

After ruling out metering problems, re-check geography.

Excessive overlap

Gap between opposing pass end trenches should be one
row space (e.g. 30in). Also check tracks for unintended
re-applications, particularly if relying on GPS mapping.

Tank or system Leak

Suspend application. Check for leaks.

Rows Not
Fertilized

Check for plugged row-unit tube

Stop application. Lift implement and inspect applicators.

No Fertilizer
Flow

Strainer plugged

Close all valves. Inspect strainer (page 80). Clean screen
as needed.

Material run-out

Check tank level.

Applicators
plugging
frequently

Applicator tips too low for coulter
depth

Raise applicator weldment (page 54).

Coulter blades too worn

Replace coulter blades.

Field too wet

Wait for drier conditions.

Applicator not level from front to rear Check implement front-to-back level (page 26).

Tractor rocking backward during
stops, or lift sequence pushing
applicators backward

Refine stopping and/or lifting technique to avoid reverse
coulter motion in ground.

Low Manifold
Pressure

Rate, speed or material viscosity too
low for orifice plate size

Re-check pump rate determination, Range sprocket, pump
dial and console setup (Option). If correct, replace orifice
plates with a smaller size (page 69).

Strainer clogged

Clean strainer, and possibly use coarser screen size
(page 71).

Ground Drive: Relief valve set too
low

Adjust relief valve (page 71).

Boom leak

Repair boom.

Tank vent closed or plugged; pump
cavitating

Check tank lid. check pump prime.

Material run-out

Refill.

High Manifold
Pressure

Orifice plate size too small

Replace orifice plates (page 69).

Applicator nozzle orifice smaller than
orifice plate.

Remove nozzle.

Orifice plates plugged

Clean plates. Check sizing.