Ground Drive Pump Troubleshooting

The CDS-John Blue NGP Pump Parts and Instructional
manual (12-M-43) has additional troubleshooting
information.

Problem

Cause

Solution

Low Rate

Ground drive on Low Range when
rate requires High

Exchange Range sprockets (page 72).

Dial setting incorrect

Re-check Range and Dial settings for rate.

Ground drive slipping

Check condition of arm and chains. Check operating height
of implement (may be too high). If soil is too wet, try
reconfiguring for a lower manifold pressure, or wait for dryer
conditions.

Pump damaged

See CDS-John Blue NGP Pump Parts and Instructional
manual.

High Rate

Ground drive on High Range when
rate requires Low

Exchange Range sprockets (page 72).

Dial setting incorrect

Re-check Range and Dial settings for rate.

Low Manifold
Pressure

Relief valve set too low

Adjust relief valve (page 71).

Ground drive on Low Range when
rate requires High

Exchange Range sprockets (page 72).

Field speed too low

Increase speed or reduce orifice plate size.

Ground drive wheel or chains
slipping

Check condition of arm and chains. Check operating height
of implement (may be too high). If soil is too wet, try
reconfiguring for a lower manifold pressure, or wait for dryer
conditions.

Product
Dumping at
Relief Valve

Rate, speed or material viscosity too
high for orifice plate size

Re-check pump rate determination, Range sprocket, pump
dial and console setup (Option). If correct, replace orifice
plates with a larger size (page 69).

Orifice plates clogged

Use larger plates (page 69) or finer strainer screen
(page 71).

Relief valve set too low

Adjust relief valve (page 71).

Applicators plugged

Clean out applicator tubes

Material slushy due to low
temperature, or actual ice in boom

Wait for warmer conditions.

High Manifold
Pressure

Ground drive on High Range when
rate requires Low

Exchange Range sprockets (page 72).

Field speed too high

Reduce speed or increase orifice plate size.