Great Plains 3N-4025P Operator Manual User Manual

Page 120

Advertising
background image

3N-4010P, 3N-4015P, 3N-4020P and
3N-4025P

196-286M

4/23/2010

118

GPS-Based Seeding

Settings for FarmWorks SiteMate used with Great Plains Precision Population Controllers - QUICK
REFERENCE GUIDE

(Create a .shp recipe file in FarmWorks Site Pro, SMS 2.0, SSToolbox, or other software that will create
a .shp file, and transfer it to SiteMate.)

SiteMate Settings: (version 8.12)

1.

Select CONFIGURE tab. Select SETTINGS. Select VARIABLE RATE SETUP. Select NEW. Type in
GP PPC. Under CONTROLLER TYPE, select Rawson from the scroll-down list. Under COMM
PORT select the port number for the serial card or flash jacket port.

2.

Select MAP tab. Enter DEFAULT rate. This will be the rate that SiteMate will call for if you are outside
the map area, GP Controller will continue applying rate it was set at when signal was interrupted, un-
til signal is regained, or another rate is set manually. If power to the SiteMate is interrupted, you will
need to restart the recipe to return to VR. In the CONVERSION window, enter the conversion rate
as follows: if your recipe (.shp file) is written using the entire number as the desired rate, i.e. 30,000
seeds/acre on the recipe means then you will need to enter the conversion multiple - in that case 1
Map Unit = 1,000 Controller Units.

3.

Under the APP tab, enter the Feed Delay as 3 seconds. Enter the Following Distance (the offset from
the Great Plains meters from the GPS) as follows: for 15’ and 20’ the distance from the opener to the
hitch pin is ______ ; for the 30’ model the distance is ______ ; Add the distance from the hitch pin
to your GPS location. Enter the total distance in the Following Distance window. Enter the Swath
Width of the Great Plains unit.

4.

Under the CTRL tab, enter the Nominal Rate as follows: Divide the highest rate on your recipe by 1.6.
This is your Nominal Rate. For example, if your highest rate is 200,000, the nominal rate is 125,000.
If your highest rate is 32, your nominal rate is 20. Enter the step as 4%. Exit VRA Controller Setup
by clicking OK button to save the settings.

5.

Under FILE, Open VRT and select the Rx Map (recipe) for the field. Press the SETUP button and se-
lect the GP PPC controller option that you have set up using these settings instructions.

6.

Press GO. The Rx rate window shows the rate that is being sent to the GP Precision Population Con-
troller. The APPLIED window shows the rate that the GP Controller is applying.

Advertising