Operating instructions – Great Plains 3N-4025P Operator Manual User Manual

Page 94

Advertising
background image

3N-4010P, 3N-4015P, 3N-4020P and
3N-4025P

196-286M

4/23/2010

92

Operating Instructions

Drive Operational Requirements:

Hydraulic System:

Closed center, pressure compensated or load sensed systems only

Drive will not operate on open-centered hydraulic systems

Minimum Hyd Pressure:

2250 psi

Maximum Hyd Pressure:

3000 psi

Maximum Required Flow:

13 gpm

Electrical System:

Voltage:

12 volt DC

Amperage:

4 amperes

Tractor Hookup

Hydraulics:

1.

Connect pressure hose (P) to retraction outlet.

2.

Connect motor return hose (T) to motor return port (if available) or extension outlet.

3.

Set flow rate at approximately 13 gpm.

4.

If tractor is equipped with electro-hydraulic valves, set timer to “constant” flow.

Electrical:

1.

Power can be connected in three different manners:

a.

Power port adapter (PN 19676)

Advertising