Great Plains 3N-4025P Operator Manual User Manual

Page 122

Advertising
background image

3N-4010P, 3N-4015P, 3N-4020P and
3N-4025P

196-286M

4/23/2010

120

(SiteMate Settings, step 4) and on the GP
Console (GP Settings, step 2); these must be
set to the same number

4.

Rates on GP Console and on SiteMate do not
match

check Nominal Rates on both the SiteMate

(SiteMate Settings, step 4) and on the GP
Console (Gp Settings, step 2); these must be
set to the same number

recheck GP calibration number with metering

wheel and row spacing.

the recipe rates for SiteMate are in 4% incre-

ments; If the two rates are within this 4%
range, the units are operating normally

check the Conversion number (SiteMate Set-

tings, step 2); if the recipe requires a target
conversion number, i.e. the recipe is for 25
which means 25,000 seeds/acre, the target
conversion number will be 1000; (In this case
the Nominal Rate in SiteMate and the GP
console should be near 25,000); see SiteM-
ate Settings, step 4 for calculating Nominal
Rate

5.

Population Monitor rate does not match GP
Controller Console

make certain that SiteMate and GP controller

Console agree; if not, see Troubleshooting,
step 4 above.

recheck GP calibration number with metering

wheel and row spacing

recheck planter monitor settings: calibration

number, row spacing, number of rows, swath
width, seed, etc.

on small seeds and/or high rates, if popula-

tion monitor consistently indicates a lower
population than the GP Controller Console,
contact monitor manufacturer for perfomance
specs for that application

6.

GPS signal is not being received by SiteMate

verify that GPS serial port (which is also the

docking port) is not set to PC connection only
(Start/Settings/Communications/PC Connec-
tions)

check GPS settings in Configure/Settings/

GPS settings/COM )typically COM1, 4800
Baud, 8 data bits, Parity None, and Stop Bits
1)

click Data tab to view GPS details