Great Plains 3N-4025P Operator Manual User Manual

Page 121

Advertising
background image

4/23/2010

196-286M

119

Veris Drive Operating Instructions

Settings for Great Plains Precision Population
Controllers:

1.

Connect SiteMate computer to console using 9-
pin serial cable as shown to the right.

2.

Follow instructions on page 9 to set Calibration
Number based on row spacing and metering
wheel.

3.

Press Function key and go to Rawson mode.
Press Function key until the Nominal Rate ap-
pears on the display. Using the Up/Down arrow
keys, set the Nominal Rate to the same number
as you set the PF3000. Once Nominal Rate is
set, press Function key until the main operating
screen appears.

4.

Press On/VR key again to toggle to VR mode.
VR should appear on the screen along with the
rate that is being sent from the SiteMate comput-
er. Verify that the rate shown on the GP Console
is the same as the recipe sent from SiteMate.
Press Engage key to activate the Precision Pop-
ulation Controller.

5.

To change rates manually when in VR mode,
simply touch the Up/Down arrow keys. This will
change the controller to the rate you select man-
ually. To return to VR, simply touch the On/VR
key to toggle back to VR mode.

Troubleshooting GPS-Based Seeding with SiteMate

1.

No Rx rate appears on SiteMate

has field been selected? Select VRT file (see

SiteMate Settings, step 5)

check recipe to verify that it is valid by viewing

Attributes for each zone in SiteMate

if recipe calls for zero rate as the default, do you

have GPS signal, or are you outside of field?

2.

Rx rate appears on SiteMate, but no Applied
Rate

make sure “go” button on SiteMate is pressed

(button should read “stop” when recipe is being
sent to GP Console)

you must be planting in order for Applied Rate to

appear

3.

Rx rate appears on SiteMate but not on GP Con-
sole

make sure GP Console is set to VR mode

double-check all cable connections

check Nominal Rates on both the SiteMate

22735

9-Pin Serial

Cable

Advertising