Compaq PROLIANT ML370 User Manual

Page 103

Advertising
background image

Diagnostics and Troubleshooting 3-49

Table 3-17
Event Messages

continued

Event Type

Event Message

Action

Processor

Correctable Error
Threshold exceeded

Processor Correctable error Threshold
passed (Slot X, Socket X)

Replace the processor.

Uncorrectable Error

Unrecoverable Host Bus Data Parity Error

Replace the processor.

Host Bus Error

Unrecoverable Host Bus Address Parity
Error

Call the service provider or Compaq
for diagnosis.

PCI Bus Error

PCI Bus Error (Slot X, Bus X, Device X,
Function X)

Power down PCI slot and replace
board

Power Subsystem

Power Supply Failure

System Power Supply Failure (Power
Supply X)

Replace power supply

Power Supply Inserted

System Power Supply Inserted (Power
Supply X)

None

Power Supply Removed

System Power Supply Removed (Power
Supply X)

None

Power Supply
Not Redundant

System Power Supplies Not Redundant

Add power supply

System Configuration
Battery Low

Real-Time Clock Battery Failing

Replace battery

Power Module Failure

A CPU Power Module (System Board,
Socket X)

Replace power module

Power Module Failure

A CPU Power Module (Slot X, Socket X)

Replace power module

Automatic Server Recovery-2

System Lockup

ASR Lockup Detected: Cause

Call the service provider or Compaq
for diagnosis.

Operating System

Blue Screen Trap: Cause [NT]

Kernel Panic: Cause [UNIX]

System Crash

Abnormal Program Termination: Cause
[NetWare]

Refer to the documentation for the
operating system.

Automatic Operating System Shutdown
Initiated Due to Fan Failure

Automatic Operating System Shutdown
Initiated Due to Overheat Condition

Automatic OS
Shutdown

Fatal Exception (Number X, Cause)

Refer to the documentation for the
operating system.

Advertising