Compaq PROLIANT ML370 User Manual

Page 53

Advertising
background image

Removal and Replacement Procedures 2-37

Compaq Integrated Smart Array Controller Upgrade
Module

NOTE: The Compaq Integrated Smart Array Controller upgrade module is an upgrade option in the
ProLiant ML370.

To remove the Compaq Integrated Smart Array Controller upgrade module:

1. Perform the preparation procedures. See “Powering Down the Server” earlier in this

chapter.

2. Open the front bezel (tower model only). See “Front Bezel” earlier in this chapter.

3. Remove the small access panel. See “Small Access Panel” earlier in this chapter.

4. Remove any I/O expansion boards. See “I/O Expansion Board” earlier in this chapter.

5. Push in the clips securing the Compaq Integrated Smart Array Controller module to the

system board

.

6. Pull the module away from the system board

.

1

2

1

Figure 2-33. Removing the Compaq Integrated Smart Array Controller upgrade module

Reverse steps 1 through 6 to replace the Compaq Integrated Smart Array Controller upgrade
module.