Table 3-2
POST Error Messages

continued

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

215 - Processor
Power Module has
lost Redundancy in
Socket x

None

PPM (DC-DC Converter) has lost
redundancy.

Run Diagnostics. Replace failed
assembly as indicated.

215 - Nonfunctioning
Voltage Regulator
Module for
Processors

None

PPM (DC-DC Converter) has
failed or lost redundancy.

Run Diagnostics. Replace failed
assembly as indicated.

216 - Voltage
Regulator Module for
Processor X no
longer redundant

None

Redundancy failed in PPM

To restore redundancy, replace
the PPM.

216 - Processor PPM
has lost Redundancy,
Module X

None

Indicated PPM (DC-DC Converter)
has lost redundancy

Replace failed assembly as
indicated.

218 - Cache
Accelerators Not
Installed. System
Halted.

None

Cache accelerators not installed
or improperly installed

Check cache accelerator
installation.

219 - Tag Update
Rules SRAM Failure.
System Halted.

None

Catastrophic chipset failure

Call Compaq service provider.

219 - Snoop Rules
SRAM Failure.
System Halted.

None

Catastrophic chipset failure

Call Compaq service provider.

220 - Cache
Accelerator Slot x
Initialization Failed.
System Halted.

None

Cache accelerator in slot x
improperly installed or bad

Check cache accelerator
installation and if properly
installed, replace.

221 - Power Fault On
Processor Bus X

None

A PPM on indicated bus is in a
failed state.

Run Diagnostics. Replace failed
assembly as indicated.

301 - Keyboard Error

None

Keyboard failure

Turn off the computer, then
reconnect the keyboard.

301 - Keyboard Error
or Test Fixture
Installed

None

Keyboard failure

Replace the keyboard.

continued