3-38 Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-16
ADU Diagnostic Messages

continued

Message

Description

Recommended Action

Adapter/NVRAM
ID mismatch

Nonvolatile RAM has an ID for a
different controller from the one
physically present in the slot.

Run the System Configuration Utility.

Array Accelerator
battery pack X
not fully charged

Battery is not fully charged.

If 75% of batteries present are fully charged,
Array Accelerator is fully operational. If less
than 75% of batteries are fully charged, allow
36 hours to recharge them.

Array Accelerator
battery pack X
below reference
voltage
(recharging)

Battery pack on Array Accelerator is
below required voltage levels.

Allow enough time for batteries to recharge
(36 hours). If batteries have not recharged
after 36 hours, replace the Array Accelerator
board.

Board in use by
Expand
operation

Array Accelerator memory is in use
by Expand operation.

Operate system without Array Accelerator board
until Expand operation completes.

Board not
attached

Array controller configured for use
with Array Accelerator board, but one
is not attached.

Attach Array Accelerator board to array
controller.

Configuration
signature is zero

ADU detected that nonvolatile RAM
contains a configuration signature of
zero. Old versions of the System
Configuration Utility could cause this.

Run the latest version of System Configuration
Utility to configure the controller and nonvolatile
RAM.

Configuration
signature
mismatch

Array Accelerator board configured
for a different array controller board.
Configuration signature on Array
Accelerator board does not match the
one stored on the array controller
board.

To recognize the Array Accelerator board, run
the Array Configuration Utility.

Controller
communication
failure occurred

Controller communication failure
occurred.

ADU was unable to successfully issue
commands to the controller in this slot.

Controller
detected.
NVRAM
configuration not
present

Nonvolatile RAM does not contain a
configuration for this controller.

Run the System Configuration Utility to
configure the nonvolatile RAM.

Controller
firmware needs
upgrading

Controller firmware is below the
latest recommended version.

Run Options ROMPaq to upgrade the controller
to the latest firmware revision.

Controller is
located in
special “video”
slot

Controller is installed in slot for
special video control signals. If
controller is used in this slot, LED
indicators on front panel may not
function properly.

Install the controller in a different slot and run
the System Configuration Utility to configure the
controller and nonvolatile RAM. Then run the
Array Configuration Utility to configure
controller.