3-28 Compaq ProLiant ML370 Maintenance and Service Guide

200-299, Memory Test Error Codes

The 200 series of diagnostic error codes identifies failures with the memory subsystem.

Table 3-4

Memory Test Error Codes

Error Code

Description

Recommended Action

200-xx

Invalid memory configuration.

Reinsert memory modules in correct location and retest.

201-xx

Memory machine ID test failed.

202-xx

Memory system ROM checksum
failed.

1.

Replace the system ROM and retest.

2.

Replace the processor board and retest.

3.

Replace the memory expansion board and retest.

203-xx

Memory write/read test failed.

204-xx

Memory address test failed.

205-xx

Walking I/O test failed.

206-xx

Increment pattern test failed

1.

Replace the memory module and retest.

2.

Replace the processor board and retest.

3.

Replace the memory expansion board and retest.

207-xx

Invalid memory
configuration-check DIMM
installation. DIMMs installed
have 8K refresh.

Replace DIMMs.

208-xx

Invalid memory speed detected -
check DIMM installation. Slow
DIMMs may cause data loss.

Replace DIMMs with timing greater than 60 ns.

209-01

RAM long test failed.

209-02

Error while saving test block.

209-03

Error while restoring test block.

209-89

ECC error during testing.

1.

Replace the memory module/board and retest.

2.

Replace the system board and retest.

3.

Replace the memory expansion board and retest.

210-xx

Random pattern test failed.

1.

Replace the memory module and retest.

2.

Replace the processor board and retest.

3.

Replace the memory expansion board and retest.

211-01

RAND test failed.

211-02

Error while saving test block

211-03

Error while restoring test block

211-04

Insufficient memory to perform the
test

211-05

Failed inverted pattern compare,
but RAM was correct

211-89

ECC error during testing

1.

Replace the memory module/board and retest.

2.

Replace the system board and retest.

214-01

Data error during noise test

214-89

ECC error during testing

1.

Replace the memory module/board and retest.

2.

Replace the system board and retest.

215

Non-functioning DC-DC converter
for processor X

Replace the DC-DC converter (Processor Power
Module).

Advertising