Diagnostics and Troubleshooting 3-21

Table 3-2
POST Error Messages

continued

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

1786 - Drive Array
Recovery Needed.
The following SCSI
drive(s) need
Automatic Data
Recovery: SCSI
port 1: SCSI ID 0.

Select F1 to continue
with recovery of data
to drive. Select F2 to
continue without
recovery of data to
drive.

Or

Slot 1 Drive Array
Recovery needed.
Automatic Data
Recovery previously
Aborted! The
following SCSI
drive(s) need
Automatic Data
Recovery: SCSI
port 1: SCSI ID 0.

Select F1 to retry
Automatic Data
Recovery to drive.
Select F2 to continue
without starting
Automatic data
Recovery data to
drive.

None

System is in Interim Data
Recovery mode. Data has not yet
been recovered.

Press F1 to allow Automatic
Data Recovery to begin. Data
will automatically be restored to
drive X now that the drive has
been replaced or now seems to
be working.

Or

Press F2 and the system will
continue to operate in the
interim Data Recovery mode.

The “previously aborted”
version of the 1786 POST
message will appear if the
previous rebuild attempt was
aborted for any reason. Run
Drive Array Advanced
Diagnostics (ADU) for more
information. If the replacement
drive was failed, try using
another replacement drive. If
rebuild was aborted due to a
read error from another physical
drive in the array, back up all
readable data on the array, run
Diagnostics Surface Analysis,
and then restore your data.

1787 - Slot x Drive
Array Operating in
Interim Recovery
Mode. The following
SCSI drive(s) should
be replaced: SCSI
port (y): SCSI ID (x)

None

Hard drive X failed or a cable is
loose or defective. Following a
system restart, this message
reminds you that drive X is
defective and fault tolerance is
being used.

1.

Replace drive X as soon as

possible.

2.

Check loose cables.

3.

Replace defective cables.

continued