Diagnostics and Troubleshooting 3-15

Table 3-2
POST Error Messages

continued

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

1731 - Fixed Disk 1
does not support
DMA Mode.

None

Hard drive error

Run the System Configuration
Utility and correct.

1740 - Fixed Disk 0
failed Set Block
Mode command

None

Hard drive error

Run the System Configuration
Utility and correct.

1741 - Fixed Disk 1
failed Set Block
Mode command

None

Hard drive error

Run the System Configuration
Utility and correct.

1750 - Fixed Disk 0
failed Identify
command

None

Hard drive error

Run the System Configuration
Utility and correct.

1751 - Fixed Disk 1
failed Identify
command

None

Hard drive error

Run the System Configuration
Utility and correct.

1760 - Fixed Disk 0
does not support
Block Mode

None

Hard drive error

Run the System Configuration
Utility and correct.

1761 - Fixed Disk 1
does not support
Block Mode

None

Hard drive error

Run the System Configuration
Utility and correct.

1764 - Slot x Drive Array Capacity Expansion Process is temporarily disabled
(followed by one of the following):

Expansion will resume when Array Accelerator has been reattached.

Expansion will resume when Array Accelerator has been replaced.

Expansion will resume when Array Accelerator RAM allocation is successful.

Expansion will resume when Array Accelerator battery reaches full charge.

Expansion will resume when automatic data recovery has been completed.

Reattach or replace Array
Accelerator, wait until the Array
Accelerator batteries have
charged, or for automatic data
recovery to complete, as
indicated.

*1766 - Slot x Drive Array requires System ROM Upgrade. Run Systems ROMPaq
Utility.

Run the latest Systems ROMPaq
Utility to upgrade the system
ROMs. Press F1 to resume.

1767 - Slot x Drive Array Option ROM is Not Programmed Correctly or may Conflict
with the Memory Address Range of an Option Card. Check the Memory Address
Configuration of installed Option Card(s) or run Options ROMPaq Utility to attempt
SMART-2/E Option ROM Reprogramming.

Remove or reconfigure
conflicting Option cards,
especially any cards that are not
recognized by the System
Configuration Utility. Try
reprogramming the ROM on the
SMART-2/E Controller using the
latest Options ROMPaq
(version 2.29 or higher).