Installing Drives

6-3

5HPRYLQJ DQG ,QVWDOOLQJ 6&6, +DUG'LVN

'ULYHV LQ WKH 'ULYH %D\V

The following subsections describe how to remove or install hard-disk drive carriers in
the storage system's drive bays.

If the storage system is connected to a Dell PERC 2, Dell PERC 2/DC, Dell PERC 2/
SC, or Dell PERC 3/DI host adapter card or another host adapter card approved by Dell
for hot-pluggable drives, you can remove and insert SCSI hard-disk drives while the
storage system is running.

Before attempting to remove or insert a drive while the storage system is running,
see the documentation for the Dell PERC 2, Dell PERC 2/DC, Dell PERC 2/SC, or Dell
PERC 3/DI host adapter card to ensure that the host adapter is configured correctly to
support drive removal and insertion.

127,&( 5HPRYLQJ DQG LQVWDOOLQJ 6&6, KDUGGLVN GULYHV ZLWK WKH VWRUDJH

V\VWHP UXQQLQJ LV QRW VXSSRUWHG IRU V\VWHPV ZLWKRXW D 'HOO 3(5&  'HOO

3(5& '& 'HOO 3(5& 6& RU 'HOO 3(5& ', KRVW DGDSWHU FDUG 5HPRYLQJ

D GULYH LQ WKLV VLWXDWLRQ ZLOO UHVXOW LQ ORVV RI GDWD

6&6, +DUG'LVN 'ULYH ,QGLFDWRU 3DWWHUQV

The three light-emitting diode (LED) indicators at the top of the hard-disk drive carriers
provide information on the status of the hard-disk drives. The storage system firm-
ware controls the drive online and drive fault indicators, while the drive itself usually
controls the activity indicator.

Table 6-1 lists the various drive indicator patterns. Different patterns are displayed as
drive events occur. For example, in the event of a hard-disk drive failure, the "drive
failed" pattern appears. After the drive is selected for removal, the "drive being pre-
pared for removal" pattern appears, followed by the "drive ready for removal" pattern.
After the replacement drive is installed, the "drive being prepared for operation" pat-
tern appears, followed by the "drive online" pattern.

7DEOH  6&6, +DUG'LVN 'ULYH ,QGLFDWRU 3DWWHUQV

&RQGLWLRQ

,QGLFDWRU 3DWWHUQ

Identify drive

All three drive status indicators flash simultaneously.

Drive being prepared for
removal

The three drive status indicators flash sequentially.

Drive ready for removal

All three indicators flash simultaneously for 30 seconds.

Drive ready for insertion

All three indicators are off.

Drive being prepared for
operation

The drive online indicator is on. The drive activity indi-
cator may flash briefly.

Drive bay empty

All three indicators are off.