Troubleshooting scsi hard-disk drives, Table 7-1 lists the indicators that can be display, 7urxeohvkrrwlqj 6&6, +dug'lvn 'ulyhv – Dell PowerVault 211S (SCSI) User Manual

Page 61

Advertising
background image

support.dell.com

Service Information for Technicians

7-3

7URXEOHVKRRWLQJ 6&6, +DUG'LVN 'ULYHV

Hard-disk drive problems can be caused by a number of conditions, including prob-
lems with the drive itself, other electronics in the system, or an interface cable.

You can resolve many hard-disk drive problems by validating the SCSI cable connec-
tions as described in Chapter 5, "Connecting Your Storage System to the Host
Computer." The SCSI bus has limits based on the type of host adapter that is con-
nected to the PowerVault 2xxS.

The optional Dell PowerEdge Expandable RAID Controller (PERC) 2, Dell PERC 2/DC,
Dell PERC 2/SC, or Dell PERC 3/DI host adapter card monitors the internal SCSI hard-
disk drives connected to the backplane board. For more information, see the Dell
PERC 2, Dell PERC 2/DC, Dell PERC 2/SC, or Dell PERC 3/DI documentation.

7DEOH  6\VWHP ,QGLFDWRUV

,QGLFDWRU V 'LVSOD\HG

&RUUHFWLYH $FWLRQ

No indicators are lighted

See "Troubleshooting a Power Supply," found later
in this chapter.

System fault indicator

and

drive fault indicator

See "Troubleshooting SCSI Hard-Disk Drives,"
found later in this chapter.

System fault indicator

and

power supply fault indicator

See "Troubleshooting a Power Supply," found later
in this chapter.

System fault indicator

and

cooling fan fault indicator

See "Troubleshooting a Cooling Fan," found later in
this chapter.

System fault indicator

Use Dell OpenManage HIP to check the system
temperature. See the HP OpenView NNM SE x.x
and Dell OpenManage HIP x.x documentation.

If a temperature fault is not indicated, see "Trouble-
shooting the System," f
ound later in this chapter.