Procedure for a nonredundant storage system, 3urfhgxuh iru d 1rquhgxqgdqw 6wrudjh 6\vwhp – Dell PowerVault 211S (SCSI) User Manual

Page 71

Advertising
background image

support.dell.com

Service Information for Technicians

7-13

3URFHGXUH IRU D 1RQUHGXQGDQW 6WRUDJH 6\VWHP

To replace the power supply in a storage system using a primary power supply only,
perform the following steps:

1.

Turn off the power switch on the power supply.

2.

Disconnect the power cable from the electrical outlet and the power supply.

3.

Using a Phillips-head screwdriver, turn the two captive screws counterclockwise
to release the power supply from the power-supply bay.

4.

Holding the handle on the power supply, carefully pull the power supply out of
the power-supply bay (see Figure 7-6).

NOTE: The power-supply handle is provided to ease the task of pulling the power
supply free from the bay. Do not use the handle to carry the Dell PowerVault 2xxS
storage system.

)LJXUH  5HPRYLQJ D 3RZHU 6XSSO\ RQ D 1RQUHGXQGDQW 6\VWHP