Installing a non-redundant power supply, System memory – Dell PowerEdge R510 User Manual

Page 114

Advertising
background image

114

Installing System Components

Installing a Non-Redundant Power Supply

NOTE:

This section is applicable to systems with cabled hard drives only.

1 Open the system. See "Opening the System" on page 87.
2 Slide the new power supply into the chassis until the power supply is fully

seated, install a bracket at the back of the power supply, and tighten the
screws to secure the power supply with the chassis. See Figure 3-18.

3 Connect the power cable to the power supply.
4 Connect all the power cables to the system board, hard drive(s),

and optical drive.

5 Plug the cable into a power outlet.
6 Replace the system cover. See "Closing the System" on page 89.
7 Turn on the system and attached peripherals.

System Memory

Your system supports DDR3 registered DIMMs (RDIMMs) or unbuffered
ECC DIMMs (UDIMMs). Single and dual-rank DIMMs can be 1067- or
1333-MHz, and quad-rank DIMMs can be 1067-MHz.

The system contains eight memory sockets split into two sets of four sockets,
one set per processor. Each four-socket set is organized into three channels.
Two DIMMs for channel 0 and a single DIMM for channel 1 and 2. The first
socket of each channel is marked with white release levers.

1

bracket

2

screws (2)

3

power supply

4

power cable 8 pins

5

optical drive power cable

6

power cable 24 pins

7

SATA power cable

book.book Page 114 Friday, November 20, 2009 2:56 PM