Dell PowerEdge R510 User Manual

Page 36

Advertising
background image

36

About Your System

E1A14

SAS cable A

failure.

Check

connection.

SAS cable A is missing
or bad.

Reseat the cable. If the
problem persists,
replace cable.

If the problem persists,
see "Getting Help" on
page 199.

E1A15

SAS cable B

failure.

Check

connection.

SAS cable B is missing
or bad.

Reseat the cable. If the
problem persists,
replace cable.

If the problem persists,
see "Getting Help" on
page 199.

E1A1D

Control panel

USB cable not

detected.

Check cable.

USB cable to the control
panel is missing or bad.

Reseat the cable.
If the problem persists,
replace cable.

If the problem persists,
see "Getting Help" on
page 199.

E2010

Memory not

detected.

Inspect DIMMs.

No memory was detected
in the system.

Install memory or reseat
memory modules.
See "Installing Memory
Modules" on page 119 or
"Troubleshooting System
Memory" on page 177.

E2011

Memory

configuration

failure.

Check DIMMs.

Memory detected,
but is not configurable.
Error detected during
memory configuration.

See "Troubleshooting
System Memory" on
page 177.

E2012

Memory

configured but

unusable.

Check DIMMs.

Memory configured,
but is unusable.

See "Troubleshooting
System Memory" on
page 177.

E2013

BIOS unable to

shadow memory.

Check DIMMs.

The system BIOS failed
to copy its flash image
into memory.

See "Troubleshooting
System Memory" on
page 177.

Code

Text

Causes

Corrective Actions