Installing System Components
Figure 3-26.
Installing and Removing the Heat Sink
10 Rotate the processor shield upward and out of the way. See Figure 3-27.
11 Lift the processor out of the socket and leave the release lever up so that
the socket is ready for the new processor.
CAUTION:
Be careful not to bend any of the pins on the ZIF socket when removing
the processor. Bending the pins can permanently damage the system board.
NOTE:
In single-processor configurations, a processor must be installed in socket
CPU1. Install the blank in socket CPU2 only.
1
heat sink heat-sink
2
retention screws (4)
2
1