Dell PowerEdge R510 User Manual

Page 40

Advertising
background image

40

About Your System

E2113

Mem mirror OFF

on DIMM ## &

##. Power

cycle AC

The system BIOS has
disabled memory
mirroring because it has
determined one half of the
mirror has had too many
errors. "## & ##"
represents the
memory-module pair
implicated by the BIOS.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Troubleshooting
System Memory" on
page 177.

I1910

Intrusion

detected.

Check chassis

cover.

System cover has been
removed.

Information only.

I1912

System Event

Log full.

Review &

clear log.

The SEL is full of events
and is unable to log any
more.

Check the SEL for details
on the events, then clear
the SEL.

I1920

iDRAC6 Upgrade

Successful

Optional iDRAC6 has
been upgraded
successfully.

Information only.

W1228

RAID

Controller

battery

capacity <

24hr.

Warns predictively that
the RAID battery has
less than 24 hours of
charge left.

Allow RAID battery
to charge to greater
than 24 hours of
sustained charge.

If problem persists,
replace RAID battery.
See "Installing the RAID
Battery" on page 147.

W1627

Power required

> PSU wattage.

Check PSU and

config.

The system configuration
requires more power
than what the power
supply can provide.

Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.

Code

Text

Causes

Corrective Actions

book.book Page 40 Friday, November 20, 2009 2:56 PM

Advertising