Go to step 14 if an error message, Indicated, go to step 14 – Dell PowerEdge R510 User Manual

Page 178

Advertising
background image

178

Troubleshooting Your System

5 Turn off the system and attached peripherals, and disconnect the system

from the electrical outlet.

6 Open the system. See "Opening the System" on page 87.
7 Remove the cooling shroud. See "Removing the Cooling Shroud" on

page 90.

8 Check the memory channels and ensure that they are populated correctly.

See "General Memory Module Installation Guidelines" on page 115.

9 Reseat the memory modules in their sockets. See "Installing Memory

Modules" on page 119.

10 Replace the cooling shroud. See "Installing the Cooling Shroud" on

page 91.

11 Close the system. See "Closing the System" on page 89.
12 Reconnect the system to its electrical outlet, and turn on the system

and attached peripherals.

13 Enter the System Setup program and check the system memory setting.

See "Memory Settings Screen" on page 65.

If the problem is not resolved, proceed with the next step.

14 Turn off the system and attached peripherals, and disconnect the system

from the power source.

15 Open the system. See "Opening the System" on page 87.
16 If a diagnostic test or error message indicates a specific memory module

as faulty, swap or replace the module.

17 To troubleshoot an unspecified faulty memory module, replace the

memory module in the first DIMM socket with a module of the same type
and capacity. See "Installing Memory Modules" on page 119.

18 Close the system. See "Closing the System" on page 89.
19 Reconnect the system to its electrical outlet, and turn on the system and

attached peripherals.

book.book Page 178 Friday, November 20, 2009 2:56 PM

Advertising