E1711

PCI parity

error on #.

Review & clear

SEL.

The system BIOS has
reported a PCI parity
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.

Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 184.

E1712

PCI system

error on #.

Review & clear

SEL.

The system BIOS has
reported a PCI system
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.

Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 184.

E1714

Unknown error.

Review & clear

SEL.

The system BIOS has
determined there has
been an error in the
system, but is unable to
determine its origin.

Check the SEL for
more information and
then clear the SEL.
Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 199.

E171F

PCI fatal

error on #.

Review & clear

SEL.

The system BIOS has
reported a PCIe fatal
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.

Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 184.

E1810

Hard drive ##

fault. Review

& clear SEL.

The specified hard drive
has experienced a fault.

See "Troubleshooting a
Hard Drive" on page 181.

E1812

Hard drive ##

removed.

Check drive.

The specified hard
drive has been removed
from the system.

Information only.