Dell PowerEdge R510 User Manual

Page 43

Advertising
background image

About Your System

43

Alert! iDRAC6 not

responding.

Rebooting.

The optional iDRAC6 is not
responding to BIOS
communication either
because it is not functioning
properly or has not
completed initialization.
The system reboots.

Wait for the system
to reboot.

Alert! iDRAC6 not

responding.

Power required

may exceed PSU

wattage.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The optional iDRAC6
has hung.

The optional iDRAC6 was
remotely reset while
system was booting.

After AC recovery, the
optional iDRAC6 takes
longer than normal to boot.

Remove AC power to the
system for 10 seconds and
restart the system.

Alert! Node

Interleaving

disabled! Memory

configuration

does not support

Node

Interleaving.

The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a memory
module has failed) so that
node interleaving cannot be
supported. The system still
runs, but without node
interleaving.

Ensure that the memory
modules are installed in a
configuration that supports
node interleaving.
Check other system
messages for additional
information for possible
causes. For memory
configuration information,
see "General Memory
Module
Installation Guidelines" on
page 115. If
the problem
persists,
see "Troubleshooting System
Memory" on page 177.

Message

Causes

Corrective Actions

book.book Page 43 Friday, November 20, 2009 2:56 PM

Advertising