Dell POWEREDGE 1955 User Manual

Page 37

Advertising
background image

About Your System

37

Error: Memory failure

detected. Memory size

reduced. Replace the

faulty DIMM as soon as

possible.

Faulty or improperly seated memory
modules.

See "Troubleshooting Server Module
Memory" on page 112.

Error: Remote Access

Controller initialization

failure.

Faulty or improperly installed
DRAC/MC module.

Reinstall the DRAC/MC module. See
"DRAC/MC Module" on page 26.

If the problem persists, replace the
DRAC/MC module.

FBD training error: The

following branch has been

disabled: Branch

x

.

The specified branch (channel pair)
contains DIMMs that are
incompatible with each other.

Ensure that only Dell qualified memory
is used. Dell recommends purchasing
memory upgrade kits directly from
http://www.dell.com or your Dell sales
agent to ensure compatibility.

Gate A20 failure

Faulty keyboard controller (faulty
server module board).

See "Getting Help" on page 127.

General failure

Operating system corrupted or
improperly installed.

Reinstall the operating system.

Keyboard controller

failure

Faulty keyboard controller (faulty
server module board).

See "Getting Help" on page 127.

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Loose or improperly connected
keyboard cable; faulty keyboard to the
custom cable; faulty keyboard
controller.

Ensure that the keyboard is properly
connected. If the problem persists,
replace the keyboard.

If the message still appears, the keyboard
controller is faulty. See "Getting Help"
on page 127.

Manufacturing mode

detected

System is incorrectly configured.

Set the NVRAM_CLR switch to "on"
and reboot the server module. See
Figure 6-2 for switch location.

Table 1-13.

Server Module Messages (continued)

Message

Causes

Corrective Actions