Installing System Options

Installing a DRAC/MC Module

1 Ensure that the DRAC/MC module release lever is fully extended. See Figure 3-4.
2 Slide the module into the chassis until it is fully seated.
3 Close the release lever until it snaps securely into place.
4 Reconnect the cables that were attached to the module.

Figure 3-4.

Removing and Installing a DRAC/MC Module

Important I/O Configuration Considerations

Ensure that you read the DRAC/MC’s readme.txt file. It contains updated information,
including system indicator behavior in certain conditions.

CAUTION:

Data loss can result if you perform certain actions on a system in which the I/O bays have

not been configured correctly. Specifically, bay 2 should have an I/O module installed only if a module
of the same fabric type is present in bay 1, and bay 4 should have an I/O module installed only if a
module of the same fabric type is present in bay 3. Except in these cases (or in a case where you
temporarily need to swap a failed I/O module in bay 1 or 3), bays 2 and 4 should be unoccupied.

Unless your system is configured according to these guidelines, do not perform any of the following
actions:

Upgrade DRAC/MC firmware

Issue a software reset command for a DRAC/MC, such as racadm racreset

1

release tab

2

release lever

3

DRAC/MC module

2

3

1