Power Supply Requirements for B

Power Supply Requirements for B

Power Supply Requirements for B

Power Supply Requirements for Blades in 48k and DCX/DCX

lades in 48k and DCX/DCX

lades in 48k and DCX/DCX

lades in 48k and DCX/DCX----4S Chassis

4S Chassis

4S Chassis

4S Chassis

Blades

Blades

Blades

Blades

Type of

Type of

Type of

Type of

Blade

Blade

Blade

Blade

48K

48K

48K

48K

@200-240

VAC

(Redundant

configurations)

DCX/DCX

DCX/DCX

DCX/DCX

DCX/DCX----4S

4S

4S

4S

@110 VAC

(Redundant

configurations)

DCX/DCX

DCX/DCX

DCX/DCX

DCX/DCX----4S

4S

4S

4S

@200-240 VAC

(Redundant

configurations)

Comments

Comments

Comments

Comments

redundant
configuration with any
number of FS8-18
Blades.

For both DCX and
DCX-4S with FX8-24
blades, (1+1) 220VAC
Power Supplies are
required for
redundancy.

FOS Feature Compatibility in Native Connectivity Modes

FOS Feature Compatibility in Native Connectivity Modes

FOS Feature Compatibility in Native Connectivity Modes

FOS Feature Compatibility in Native Connectivity Modes

Some FOS features are not fully supported when operating in the native connectivity modes for deployment
with M-EOS based products. All Brocade models that are supported by Fabric OS v6.4 support both
interopmodes 2 and 3 with the exception of the Brocade 4100 and 8000 and DCX/DCX-4S with one or more
FCOE10-24 blades.

The following table specifies the support of various FOS features when operating in either interopmode 2
(McDATA Fabric Mode) or interopmode 3 (Open Fabric Mode) with Fabric OS v6.4

.

FOS Features

FOS Features

FOS Features

FOS Features (supported in interopmode 0)

FOS v6.4

FOS v6.4

FOS v6.4

FOS v6.4

IM = Interopmode

IM = Interopmode

IM = Interopmode

IM = Interopmode

IM 2

IM 2

IM 2

IM 2

IM 3

IM 3

IM 3

IM 3

L2 FOS Hot Code Load

Yes

Yes

FOS Hot Code Load with FCR

Yes

Yes

Zone Activation Support

Yes

Yes

11

Traffic Isolation Zones

1

Yes

No

Frame Redirection (devices attached to FOS)

1

Yes

Yes

11

Frame Redirection (devices attached to M-EOS)

1

Yes

Yes

11

Frame Redirection over FCR

10

Yes

Yes

11

FCR Fabric Binding (route to M-EOS fabric with Fabric binding)

9

Yes

Yes

L2 Fabric Binding

Yes

No*

DCC policies

No

No

SCC policies

Yes

4

No*

E/EX_Port Authentication

Yes

Yes

ISL Trunking (frame-level)

Yes

2

Yes

2

Dynamic Path Selection (DPS, exchange based routing)

Yes

3

Yes

3

Dynamic Load Sharing (DLS, port based routing)

Yes

Yes

Virtual Channels (VC RDY)

Yes

2

Yes

2

FICON Management Server (Cascading)

Yes

No*

FICON MIHPTO

Yes

No*

Full Scalability (to maximum M-EOS fabric limits)

Yes

Yes