Defect ID: DEFECT000270825

Technical Severity: Medium

Summary: Expose all 64 bit port stats counter through SNMP

Symptom: 64 bit port stats is only available in CLI via portStats64Show, it's not exposed through

SNMP.

Feature: Mgmt Embedded - SNMP

Function: Other

Probability: Low

Found in Release: FOS6.4.0

Defect ID: DEFECT000273725

Technical Severity: Medium

Summary: Detected termination of webd and triggered call home event.

Symptom: At a customer site, webd terminated and restarted from time to time. At the same time as

the webd crash, HA status temporarily went to non-redundant, which triggered a Call Home
event. webd was killed by watchdog as webd was waiting for a reply from a busy httpd and
webd did not have a timeout mechanism. No other functional impact observed besides call
home event.

Feature: Field Escalation

Function: Management Services

Probability: Low

Found in Release: FOS6.2.0

Service Request ID: 412187

Defect ID: DEFECT000286033

Technical Severity: Medium

Summary: Bottleneckmon cannot be enabled on F-ports with "Locked G_Port" AND "Disabled E_Port"

enabled in portcfg.

Symptom: Customer is not able to enable bottleneckmon --enable <port> on switches with message

"Error: port is not an F_Port". The command works as expected after disable Locked G_Port
option. This error happens only when both "Locked G_Port " AND "Disabled E_Port"
parameters are "on" in portcfgshow.

Workaround: Disable either or both "Locked G_Port " AND "Disabled E_Port" features; However,

changing these features is disruptive.

Feature: Field Escalation

Function: OS: Configuration

Probability: High

Found in Release: FOS6.3.1

Service Request ID: 423357

Defect ID: DEFECT000298078

Technical Severity: Medium

Summary: Backup to all cleartext containers using tape application (Netbackup) in a multiplex/stream

environment results in a Brocade Encryption Switch fault

Symptom: The system will fault and result in tape flows halting.

Feature: Data Security

Function: Tape Encryption

Probability: Medium

Found in Release: FOS6.3.0

Service Request ID: 429393