Close with Code Change in Fabric OS v6.4.0b

Fabric OS v6.4.1 Release Notes v1.0

Page 54 of 62

Defect ID: DEFECT000298268

Technical Severity: Medium

Summary: I Series tape I/O stops with tape pipelining enabled

Symptom: Tape I/O with I Series server is not possible with tape pipelining enabled.

Workaround: Disable / do not enable tape pipelining.

Feature: FCIP

Function: FCIP I/O

Probability: Medium

Found in Release: FOS6.4.0

Defect ID: DEFECT000298400

Technical Severity: Medium

Summary: DCFM encryption support is unable to import large-sized encryption certificates

Symptom: When importing certificates that contain both the text and Base64 encoded portion of a

cert, the import will fail although DCFM encryption support does not report that it fails and
reports a success.

Feature: Data Security

Function: Infrastructure

Probability: Medium

Found in Release: FOS6.4.0

Defect ID: DEFECT000300066

Technical Severity: Medium

Summary: Data Security, EE in a DCX type chassis can fail to properly accomodate CTC upon EG re-

creation

Symptom: Containers created before EG is deleted do not show up in the fabric post EG re-creation

with chassis hosting FS8-18 blades.

Workaround: slotpoweroff/slotpower on of FS8-18 blade for CTCs to be hosted after EG re-creation.

Feature: Data Security

Function: Infrastructure

Probability: Low

Found in Release: FOS6.4.0

Defect ID: DEFECT000300754

Technical Severity: Medium

Summary: In large configurations, applying TI Zone failover disabled is causing FCP traffic over VEX to

throttle back

Symptom: Applying new TI Zone with failover disabled, FCIP performance (throughput) gets impacted.

Feature: FCIP

Function: FCIP I/O

Probability: Medium

Found in Release: FOS6.4.0