Close with Code Change in Fabric OS v6.4.1

Fabric OS v6.4.1 Release Notes v1.0

Page 43 of 62

Defect ID: DEFECT000298571

Technical Severity: Medium

Summary: "(DLS)" label needs to be removed from the "Dynamic Load Sharing" and "Lossless" group

boxes that show up in the Webtools Switch Administration Routing Tab

Symptom: Confusion due to ambiguous text in Webtools for "Dynamic Load Sharing" and "Lossless" in

the Routing Tab group box under Switch Administration.

Feature: WebMgmt

Function: Switch Admin

Probability: Low

Found in Release: FOS6.4.0

Defect ID: DEFECT000298920

Technical Severity: Medium

Summary: QoS priority traffic distribution over an FCIP tunnel may be incorrect with large amounts of

outstanding I/O, due to resource depletion at high IO rates.

Symptom: QoS circuits running over a 1G/10G bandwidth circuit will have incorrect QoS distributions

with large I/O, resulting in QoS priority traffic distribution not being enforced properly over
an FCIP Tunnel. Customer using QoS zoning may see performance issues

Feature: FCIP

Function: FCIP I/O

Probability: Medium

Found in Release: FOS6.3.1

Where Else Fixed: FOS6.3.2

Defect ID: DEFECT000298963

Technical Severity: Medium

Summary: Weblinker keeps unused file descriptors caused FFDCs and RAS-1004 Software 'Verify'

errors every 3 minutes on a VF, filling up the RASLOG.

Symptom: On a switch being managed by DCFM or Webtools, with VF enabled and Radius server

configured, customer may see RAS-1004 Software 'Verify' errors every 3 minutes on each
VF, filling up the RASLOG and causing en eventual FFDC event in other system modules du

Feature: Field Escalation

Function: OS: Infrastructure

Probability: Medium

Found in Release: FOS6.3.1

Service Request ID: 430447

Defect ID: DEFECT000299528

Technical Severity: Medium

Summary: When running tape operations using tape pipelining in a Brocade 7800 or FX8-24 blade,

the FCP_CONF command may be dropped, causing the tape operation to fail.

Symptom: I Series I/O stops with tape pipelining enabled, causing tape operations running over a

Brocade 7800 or FX8-24 blade to not complete successfully.

Feature: FCIP

Function: Emulation

Probability: Low

Found in Release: FOS6.3.1

Where Else Fixed: FOS6.3.2