Closed with Code Change in Fabric OS v6.4.0b - GA June 25, 2010

This section lists the defects with Critical, High and Medium Technical Severity closed with a code change
as of June 25, 2010 in Fabric OS v6.4.0b.

Defect ID: DEFECT000283335

Technical Severity: High

Summary: A device with a node WWN of zero connected to an NPIV port queried by CALD causes the

switch to panic and reboot

Symptom: CALD causing switch to panic and reboot about every 20-30mins. It was observed after a

recent upgrade to a partner management application.

Feature: Field Escalation

Function: Management Embedded

Probability: Medium

Found in Release: FOS6.2.1

Service Request ID: 421461

Defect ID: DEFECT000299814

Technical Severity: High

Summary: IP addresses are allowed to be deleted even if in use by a route

Symptom: Tunnel configuration anomalies.

Workaround: Issue portcfgshow iproute to find any invalid route entries and delete them.

Feature: FCIP

Function: Other

Probability: High

Found in Release: FOS6.4.0

Defect ID: DEFECT000300728

Technical Severity: High

Summary: The LUNs contained in a CTC (Crypto Target Container) lose their paths when a non-

encryption switch connecting the host and target is rebooted.

Symptom: When two BES switches are connected via a single path through a non-encryption switch,

the path between the host and the LUNs can be lost when the non-encryption switch is
rebooted. This only happens when the HA Cluster (HAC) is set for manual failback, and will
also not be observed if there are multiple paths through the fabric so that the loss of one
switch does not create a temporary loss of path.

Feature: Data Security

Function: HA Cluster

Probability: Medium

Found in Release: FOS6.4.0

Defect ID: DEFECT000301448

Technical Severity: High

Summary: Build Fabric sent to Access Gateway with F-Port trunking.

Symptom: When F-Port trunking is activated and after the master trunk goes offline, the switch will

add the new master trunk to the list of ports, which will send EFP/BF/DIA flood. The ports
will remain in this state until all N-Ports are taken offline and logged back into the fabric
again. Build Fabric (BF) sent to AG and AG forwarding the BF to redundant fabric caused
fabric disruption.

Feature: FC Services

Function: Fabric

Probability: Medium

Found in Release: FOS6.4.0

Service Request ID: 432859