Closed with Code Change in Fabric OS v6.4.0a - GA June 4, 2010

This section lists the defects with Critical, High and Medium Technical Severity closed with a code change
as of June 4, 2010 in Fabric OS v6.4.0a.

Defect ID: DEFECT000271043

Technical Severity: High

Summary: As a result of firmwaredownload, systemverifcation test, or blade insertion, occasionally

blade FCoE10-24 may turn faulty 21

Symptom: Slotshow indicates that FCoE10-24 is found to be in a faulty state

Workaround: slotpoweroff/on the FCoE10-24 to clear the faulty state

Feature: CEE-Infrastructure

Function: ANVIL DRIVER

Probability: Medium

Found in Release: FOS6.4.0

Defect ID: DEFECT000290749

Technical Severity: High

Summary: FICON: FRU events are not generated on the operator's console for removal or insertion

Symptom: No FRU event notification at the operator's console

Feature: FICON

Function: Ficud

Probability: Medium

Found in Release: FOS6.4.0

Defect ID: DEFECT000296886

Technical Severity: High

Summary: Rare corner case of Lossless being disabled after several downgrade and upgrade

scenarios.

Symptom: A DCX logical switch with port based routing, IOD (In-Order Delivery), DLS, and LosslessDLS

enabled running Fabric OS v6.3.0b is updated to v6.4.0, Lossless gets disabled.

Workaround: Re-enable Lossless / IOD on logical switches that were previously enabled.

Feature: 8G Platform Services

Function: Routing

Probability: Low

Found in Release: FOS6.4.0

Defect ID: DEFECT000297733

Technical Severity: High

Summary: With FMS enabled, after moving all ICL and 254 FC ports into a logical switch with zero

based addressing, port 1/0 (area 00) is incorrectly disabled

Symptom: Port 0 with area 0x00 is disabled

Workaround:

Feature: 8G Platform Services

Function: FOS Kernel Drivers

Probability: Medium

Found in Release: FOS6.4.0