Defects – Dell POWEREDGE M1000E User Manual

Page 34

Advertising
background image

Defects

Closed with Code Change in Fabric OS v6.4.1

This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
October 7, 2010 in Fabric OS v6.4.1.

Defect ID: DEFECT000319291

Technical Severity: Critical

Summary: In a dual Inter-fabric Link (IFL) FCR fabric with LSAN Matrix configured and LSAN binding

enabled, disabling the EX_Port for one of the IFLs causes all FCR devices to be removed
from the name server database.

Symptom: In an FCR fabric with LSAN Matrix configured, if there are two IFLs from a FCR to one edge

fabric and LSAN binding is enabled, then when one of the EX_Ports is disabled, all imported
devices corresponding to this edge fabric are dropped from name server.

Feature: 8G FCR

Function: FCR Daemon

Probability: Low

Found in Release: FOS6.4.0

Service Request ID: 451063

Defect ID: DEFECT000319434

Technical Severity: Critical

Summary: Originator source ID sent by FCR in the header and in the body of the TAPE REC command

frame do not match. This causes the command to fail.

Symptom: The Tape REC command fails in an FCR environment, causing corrupted data on the tape.

Feature: 8G FCR

Function: FCR Daemon

Probability: High

Found in Release: FOS6.4.0

Service Request ID: 450651

Defect ID: DEFECT000319598

Technical Severity: Critical

Summary: Functional fans are flagged as bad with error code "[PLAT-5042], FAN I2C reset” messages

in the Raslog.

Symptom: One or more fans go into a faulted state on the DCX chassis even though the fans are

operating properly.

Workaround: Reseat the fan reported as faulty.

Feature: System Controls/EM

Function: Infrastructure

Probability: Medium

Found in Release: FOS6.4.0

Service Request ID: 451479