Replacing a gbic module, Removing a gbic module, Installing a gbic module – Dell PowerVault 51F (8P Fibre Channel Switch) User Manual

Page 111: Replacing a gbic module -3, Removing a gbic module -3, Installing a gbic module -3, Figure 6-2, Gbic module -3, Figure 6-3, Squeeze prongs on gbic module -3

Advertising
background image

support.dell.com

Repair and Replacement

6-3

Replacing a GBIC Module

GBIC modules are installed and removed by inserting them into the system board
from the front of the unit. Simple Network Management Protocol (SNMP) traps are
generated upon GBIC insertion and removal.

Removing a GBIC Module

1.

Pull down the metal swing bar on the front of the GBIC and pull it out, as shown
in Figure 6-2.

2.

Carefully wiggle the GBIC from side to side to unseat it.

Figure 6-2. GBIC Module

If the module has squeeze prongs, squeeze the side prongs and carefully pull the
GBIC out, as shown in Figure 6-3.

Figure 6-3. Squeeze Prongs on GBIC Module

Installing a GBIC Module

To install a GBIC module with squeeze prongs, insert the GBIC module into the port
until its connector is firmly seated into the appropriate port. The latch prongs will lock
and prevent the GBIC’s accidental removal.

NOTE: The GBIC module is keyed so it can be inserted in only one way. Do not force
the insertion if the module does not slide in easily.

swing bar

squeeze prongs