Adjusting the Bezel Position

If you are installing the switch in a non-Dell rack, you may need to adjust the bezel
position to allow the rack doors to close properly. To adjust the bezel position, perform
the following steps:

1.

Remove the screws and mounting clip from one side of the bezel (see
Figure 1-5).

2.

Adjust the bezel tab so the front holes are aligned with the mounting holes on
the manifold (see Figure 1-5).

3.

Replace the mounting clip and screws.

4.

Repeat these steps for the other side of the bezel.

Figure 1-5. Adjusting the Bezel Position

Installing the Outer Slides

To install the outer slides in the rack, perform the following steps:

1.

Align the holes of the stationary and adjustable brackets with the holes in the
rack.

The stationary brackets attach to the front of the rack. The adjustable brackets
attach to the back. The top hole of each bracket must align with the top hole of an
Electronic Industries Association (EIA) unit in the rack. The top hole of an EIA unit
has a dot next to it (see Figure 1-6).

NOTE: The slides must be mounted within 1 EIA unit. The height of the switch
takes up 1 EIA unit.

10-32 x .25-inch
screws (2)

mounting clip

back holes (2)

front holes (2)

bezel tab