Error messages by firmware module, Figure a-1, Table a-1 – Dell PowerVault 51F (8P Fibre Channel Switch) User Manual

Page 140

Advertising
background image

A-2

Installation and Troubleshooting Guide

Figure A-1. errShow Command Example

To display error messages via Telnet:

1.

From the prompt, type

errShow

.

2.

To scroll through the error list, type

CR.

3.

Scroll through the error log (if no errors were encountered, the message

No

Error

appears).

Error Messages by Firmware Module

Table A-1 shows the error messages organized by module.

=> errShow

Error 02
--------
0x103dc470 (tSilkworm): Apr 9 10:41:06
Error SENSOR-FAILED, 3, sensor 7 (Fan 2) is below minim

Type <CR> to continue, Q<CR> to stop:

Error 01
--------
0x103dc470 (tSilkworm): Apr 9 10:40:51
Error DIAG-TIMEOUT, 1,
Port 2 receive timeout.

Type <CR> to continue, Q<CR> to stop:
value = 1 = 0x1

Table A-1. Errors

Module

Error

Severity

Explanation

Action

Flood

INVLSR (3)

An unknown Link
State Record has
been received
from a neighbor
switch.

Check that all paths and
routing tables are correct
using the commands
uPathShow <domain>, or
uPathAllShow.
If the paths are not correct
reboot the neighbor switch
that sent the wrong data.
Check the paths and routes
again. If they are still incor-
rect, reboot the local switch.