Table 4-16, Switchshow command field descriptions -30 – Dell PowerVault 51F (8P Fibre Channel Switch) User Manual

Page 92

Advertising
background image

4-30

Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

Table 4-16. switchShow Command Field Descriptions

Field

Description

switchName

The switch name.

switchType

Model number and system board revision level. The model
number is as follows:

1 = PowerVault 50F
2 = Reserved
3 = PowerVault 51F

switchState

The state of this switch: online, offline, testing or faulty.

switchRole

There are three possibilities for switchRole including:

Principle — The principal switch as defined in FC-SW

Subordinate — This switch is enabled and is a subordi-
nate switch

Disabled — The switch is disabled.

switchDomain

The domain ID of this switch: 0 to 31 or 1 to 239.

switchID

The domain ID of this switch's embedded port: hex fffc00 to
fffc7f.

switchWwn

The WWN of this switch. The WWN is a unique identifier for
each switch and is assigned by the manufacturer. A number-
ing scheme administrated globally assures that this WWN is
unique to each switch.

Port Number

One line per port is printed after the switch summary. Each
line shows the port number: 0 to 15, the GBIC type, the port
state and a comment field.

GBIC type

The GBIC type follows the port number. The five GBIC types
include:

-- — No GBIC present
sw

Shortwave GBIC

lw

Longwave GBIC

cu

Copper GBIC

id

Serial ID

Advertising