Figure 1-6, Mounting the outer slides in the rack -9 – Dell PowerVault 51F (8P Fibre Channel Switch) User Manual

Page 37

Advertising
background image

support.dell.com

Installing the Dell PowerVault 51F Switch

1-9

Figure 1-6. Mounting the Outer Slides in the Rack

2.

Use four 10-32 x 1/2-inch screws and four tapered washers to mount each outer
slide in the rack, as shown in Figure 1-6.

The screws are threaded through the washers, the rack, and into the top and
bottom holes of the brackets, leaving the middle bracket holes open.

3.

Fully tighten the screws and then back them out about two turns.

Leaving the outer slides loose makes it easier to align the outer slides and the
inner-slide rails.

stationary
bracket

10-32 x 1/2-inch
screw (8)

outer slide

adjustable
bracket

tapered
washer (8)