Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

uptime

The uptime command can be used to display the amount of time the switch has been
in operation (also known as up time), the total cumulative amount of up time since the
switch was first powered-on, the date and time of the last reboot, and the reason for
the last reboot.

For up and powered-on times less than 60 seconds, the display granularity is by the
second. For times greater than 60 seconds, the display granularity is by the minute. In
addition, the formatting of the output adjusts based on the amount of time. See
Appendix A, “Error Messages,” for more information.

version

The following example shows the version command screen, which displays firmware
version information and build dates. The fields are described in Table 4-17.

License Commands

License commands are reserved for use by Dell only.

Table 4-17. version Command Field Descriptions

Field

Description

VxWorks version

VxWorks operating environment version used on the
processor

Firmware
version

Switch firmware version

Made on

Firmware release date and time

Flash

The build date of the firmware stored in flash memory

BootProm

The build date of the firmware stored in the boot PROM

switch:admin> tempShow

31 27 28 27 33 Centigrade

87 80 82 80 91 Fahrenheit

switch:admin> version

VxWorks version: 5.3.1

Firmware version: v2.0

Made on: Thu Nov 19 16:18:29 PST 1998

Flash: Mon Dec 28 15:34:05 PST 1998

BootProm: Thu Oct 1 13:34:29 PDT 1998