Error Messages

A-5

NBFSM

NGBRSTATE (2)

An error occurred
in the neighbor
Finite State.

Check the neighbor’s state
with the nbrStateShow
command.
If the state is not
NB_ST_FULL, force a state
change with the
portDisable command fol-
lowed by portEnable.
After a few seconds, if the
state is not NB_ST_FULL,
reboot both the local and
remote switches.

UCAST

ADDPATH (1)

A static path con-
figuration failed.

Check command
parameters.

RELICPDB (2)

The path selec-
tion task received
an E_Port SCN,
but the port was
already ISL.

Run the ucastAllShow
command. Contact cus-
tomer support.

SPFCOST(3)

An error occurred
with computing
the unicast path
tree.

Run the LSDAllShow com-
mand. Contact customer
support.

MQ

QREAD (1)

A task was
unable to receive
a message.

Run the command show

<queue ID> with the ID of
the queue reported in the
error. Contact customer
support.

QWRITE (1)

A task was not
able to post a
message on a
queue.

See “MQ-QWRITE Error”
found later in this chapter for
more information.

SYS

NOMEM (1)

The system’s
memory is
exhausted.

Reboot the switch. Contact
customer support.

SYSCALL (2)

A system call into
VxWorks failed.

Reboot the switch. Contact
customer support.

TIMERS

ENQFAIL (1)

An error occurred
while setting a
timer.

Reboot the switch. Run the
commands
actTimersShow

and

timerShow <timer ID>.
Contact customer support.

Table A-1. Errors (continued)

Module

Error

Severity

Explanation

Action