Installation and Setup

Storage Tiers and Storage Profiles

After installation, ESSDs are automatically assigned to Storage Tier 1 and all other
available disks classes are moved down to a lower tier. The following tables show how the
Storage Tiers and corresponding disk classes are re-assigned after adding ESSDs to a
Storage Center:

System-provided Storage Profiles that use Storage Tier 1 (Recommended or High),
automatically allow associated volumes to use the ESSDs. See

Configuring Storage

Profiles on page 404

for details on configuring Storage Profiles to make the best use of

ESSD storage.

Installation and Setup

Installing the Hardware

Enterprise Solid State Drives (ESSDs) are allowed in slots 2 thru 15 of an SBOD enclosure
(up to 14 per enclosure). In addition, slots 1 and 16 must contain fiber channel drives. For
maximum IOs per second, use two SBOD enclosures with two ESSDs each.

For details on inserting drives into enclosures, see the Storage Center System Setup
Guide
. For details on installing SBOD enclosures, see the Storage Center System
Connectivity Guide
.

Storage Tier

Existing Disk Type

Disk Type After ESSD Install

Tier 1

15K

ESSD

Tier 2

10K

15K, 10K

Tier 3

7K

7K

Storage Tier

Existing Disk Type

Disk Type After ESSD Install

Tier 1

15K

ESSD

Tier 2

7K

15K

Tier 3

7K

7K

Storage Tier

Existing Disk Type

Disk Type After ESSD Install

Tier 1

15K

ESSD

Tier 2

15K

Tier 3

10K

10K

Tier

Existing Disk Type

Disk Type After ESSD Install

Tier 1

10K

ESSD

Tier 2

7K

10K

Tier 3

7K

7K