68

Reboot: when the DVR system reboot without abnormal condition, the system will send out
the alarm message.

Abnormal Reboot: when the DVR system reboot in irregular condition, the system will send
out the alarm message.

Recording is switched off: when the recording has been stopped, the system will send out
the alarm message.

Network is switched off: when the network connection of DVR system is lost, the system
will send out the alarm message.

Hard Disk failed: when the hard disk doesn

’t work normally, the system will send out the

alarm message.

-

Continue trigger duration: Set a time period that when sensor has been trigger and stay in the
same status for that period, then the alarm will be sent out.

7. In (6) Alarm Reset, click the camera number to set the reset condition of alarm. Once alarm is reset,

all alarm action will stop at the moment. If the sensor normal status is high, set the alarm reset
condition to low.

8. In (7) Action, you may now set the alarm action for the system to perform when the alarm condition is

activated.

- Enlarge Camera View

Switch to only display video in Preview mode from where the alarm is activated.
a. Select the camera from drop down list to specify which camera video to be enlarged on screen

when the alarm is triggered.

b. Retrieve time: set the waiting duration before system switching back to original Preview mode.

If the retrieve time is un-mark, the alarm video will keep enlarging until user switch back to
Preview mode manually. The retrieve time range is 0~ 600 seconds.

- Relay Output

Set to enable/disable the relay operation when the alarm is
activated and to extend additional time in second before it
stops the relay operation.
1. Next to the Relay Output check box, click Detail.
2. In the Alarm Relay dialog box, select from the available

relay list and in the ON column, set to enable/disable the
relay operation when the alarm is activated.

3. In the Retrieve time check box, you may enable/disable to

extend the relay operation time and set the duration in
second.

4. Click OK to exit and accept the setting and Cancel to exit

without saving the setting.

Advertising