3 test mode flow, 4 key functions – Rice Lake Ishida IGX & IGB Series - Service Manual User Manual

Page 11

Advertising
background image

Manual No. 085-3435-07

10/45

IGB/IGX Series (Overseas Specifications) Service Manual

2.1.3 Test Mode Flow

C 1

C 2

C 8 , C 9

C 7

C 3 to C 6

T o e a ch C 1
m o d e se tu p

K e y ch e c k
m o d e

E a ch m o d e
o p e ra tio n

S ca le fu n ctio n
S e tu p m o d e

E a ch m o d e
o p e ra tio n

2.1.4 Key Functions

Key Function

Turns the power ON or OFF for the IGB Series.

Turns the power ON or OFF for the IGX Series.
+5V is always supplied to the circuit voltage.

Increases the numeric value (when the numeric value is set).
Advances the mode (when conditions are set).
Adjusts the zero point.

Decreases the numeric value (when the numeric value is set).
Reverses the mode (when conditions are set).
Adjusts the span point.

Determines the data in the Details Mode.


Changes between “+ Adjust” (ZERO ³ key [u display]) and “- Adjust” (TARE key
[d display]) when the span is adjusted.
Returns to each mode.

Memory

switch

(Tact switch on the main board)
Saves the E2ROM data of each item setting of C1 mode.

Advertising